Radiator And Cooling Systerm Protectant Not Susceptible To Corrosion, Long Service Life Aug 11, 2017

Central heating real estate, water pressure is guaranteed, the Radiator and Cooling Systerm Protectant water from the general unrestricted. If the use of wall-mounted boiler heating, water pressure will be relatively small, the water should not be too high, the best choice of 1.5 meters below the height, otherwise the heating effect will be greatly reduced, the Radiator and Cooling Systerm Protectant will cool half of the heat. If the use of coal-fired heating furnace heating, with the matching is the cast iron Radiator and Cooling Systerm Protectant.

Centralized heating system is divided into two kinds of closed and open, closed to prevent the entry of oxygen, the system is not susceptible to corrosion, long life, choose a wide range of Radiator and Cooling Systerm Protectants; open investment less, the system vulnerable to corrosion, easy aging , Easy to leak, the best configuration of corrosion-resistant products, such as aluminum, copper and aluminum composite Radiator and Cooling Systerm Protectant. Different water distance, different columns of a group of Radiator and Cooling Systerm Protectant and Cooling Systerm Protectant conduction heat is different, the choice should be based on the room area accurate calculation, to avoid the "big horse car" or "small horse cart" phenomenon. High-rise buildings if the use of centralized heating water pressure is very large, should choose better pressure performance of steel and cast iron Radiator and Cooling Systerm Protectant, to avoid the phenomenon of burst.

1, the Radiator and Cooling Systerm Protectant to ensure that internal airless

The Radiator and Cooling Systerm Protectant should not be in the case of partial water discharge, as this will speed up the corrosion. For long-term use of the generator unit, to dry or fill the water, use distilled water or natural soft water, and adding anti-rust agent.

2, pay attention to the Radiator and Cooling Systerm Protectant coolant

Usually very hot and compressed. Do not clean the Radiator and Cooling Systerm Protectant or remove the tubing when not cooling. Do not operate the Radiator and Cooling Systerm Protectant or turn on the fan cover when the fan is rolling.

3, external cleaning should pay attention

The heatsink can be blocked by debris, insects, etc., which will affect the power of the Radiator and Cooling Systerm Protectant. Regular finishing of these light deposits can be sprayed with low pressure hot water with a cleaning agent to evaporate steam or water from the front of the Radiator and Cooling Systerm Protectant to the fan. Such as erupting from the opposite direction will only push the dirt into the middle. When using this method, use the cloth to pick the generator set.

Working pressure refers to the maximum pressure that the Radiator and Cooling Systerm Protectant is allowed to run, in megabytes, expressed in English as mpa. Under normal circumstances, the steel Radiator and Cooling Systerm Protectant working pressure of 0.8mpa, copper and aluminum composite Radiator and Cooling Systerm Protectant working pressure of 1.0mpa.

Test pressure is to test the airtight airtight and strength of the necessary technical requirements, is the working pressure of 1.2-1.5 times, such as Radiator and Cooling Systerm Protectant manufacturers in the production process to test the airtight air pressure pressure is 1.5-2.0 mpa, Pressure to test pressure after the stability of a minute, the welding is not deformed, no leakage is qualified.

There is gas in the Radiator and Cooling Systerm Protectant. Performance: a group of Radiator and Cooling Systerm Protectants have a few pieces of hot pieces of heat is not hot, for the bathroom Radiator and Cooling Systerm Protectant is below the heat is not hot, or Radiator and Cooling Systerm Protectant water flow and so on. In particular, the first half of the year before the beginning of heating, because the entire district heating system in the gas more, this situation often occurs. Solution: often open the Radiator and Cooling Systerm Protectant on the exhaust valve exhaust, until the water out of the bubble so far.

The manifold valve is not open. Performance: some Radiator and Cooling Systerm Protectant and Cooling Systerm Protectant heat, and some are not hot. Solution: Detection of each valve on the sub-valve has not opened, if not open, the valve handle can be screwed to parallel with the branch can be.

The thermostat on the Radiator and Cooling Systerm Protectant is not open. Performance: Radiator and Cooling Systerm Protectant is not hot. Solution: Check the heat of the Radiator and Cooling Systerm Protectant into the water temperature control valve has not opened. Clockwise direction for the small (S direction), counterclockwise direction to open large (O direction), if not open or open smaller, then counterclockwise rotation can be in the end.